http://WWW.SDAUTOMATIONCONTROL.COM
http://WWW.SDAUTOMATIONCONTROL.COM

Checking delivery availability...

background-sm
Search

Updates found with 'vibration monitoring system'

Page  2 1

Updates found with 'vibration monitoring system'

With the aid of our vast manufacturing unit, we are engaged in offering a wide range of Programmable Logic Controller. All our products are manufactured and developed following the international quality norms and standard at our vendor-base. To meet the varied requirements of our customers, we also offer our range is various specifications.Specification:Communication operation up to 5 port covering RS 232, RS 485, Ethernet, GSM & USBMaximum 512 points of digital input/outputFull range of peripherals (AI/A0, DI/D0, TC/RTD /LC, on Board Cards & Com ports)Open communication Protocol for HMI, SCADA and OPC ServersClose-loop control instructionsWindow-based programming software with editing capability of run time programFast, powerful processors, high speed basic instructions-performance-0.2 sec/STEPControl up to 384 digital I/O points that allows up to 384 points (192 points using terminal blocks)Various I/O types & specialty modulesDigital out: Relay, transistor (16 point, 32 point), SSR, combo I/OSpecial I/O: A/D (8Ch. 4Ch), D/A (4Ch, 2Ch). RTD (4Ch), TC (4Ch), Pulse (4Ch HSC) SCU (2Ch serial data comm.) and link networkRange of I/O base options (up to 12 slot) when configuring a system that enables the user to choose a backplane from 2.3. 5, 6, 8. 10 and 12 slotsHigh capacity programming and memory backup option program memory size is from 9.6k words (LX70-CPU70P1) up to 20k words (for LX70-CPU70P2). Built-in flash EEPROM retains all ladder logicBuilt-in PID capabilities and supports 8-loop PID controls (Only for LX70-CPU7OPi module)Built-in RTC (Real time clock) that supports programming by time and date. (Only for LX70-CPU70P2 module)Built-in RS 232C and RS 485.2 port (LX70-CPU70P2 module) Two communication channels for simple connectivity to computers, operator interface, modem and other controllers to exchange large volumes of data with high-speed Superior diagnostics, self-diagnostics to minimize system errors and to maximize diagnostic efficiencyLX soft programming software LX soft programming software let create, modify and monitor CPU, forced I/O, I/O configuration. It is a powerful easy-to-use tool for program upload/download.
Send Enquiry
Read More
IR3038-variable Profibus PA Remote IndicatorQuotation DownloadsThe IR303 receives up to 8 variables (float + status) via cyclical communication with the Profibus-DP class 1 Master and enables them on the LCD display. It works with any Profibus-DP mater and is ideal for applications with the TT383, 8-channel Profibus-PA temperature transmitter or any other Profibus equipment. CommunicationDigital only. PROFIBUS-PA, 31.25 Kbits/s voltage mode, according to IEC 61158-2.Current Consumption12 mA from PROFIBUS-PA network.Function Blocks8 AO output blocks that receive the 8 variables+status via SetPoint (SP) that will be displayed on the LCD. On LCD display the mnemonics must be configured up to 5 characters.Turn on TimeApproximately 10 seconds.Humidity Limits0 to 100% RH.Classified Area CertificationExplosion proof, weather proof and intrinsically safe (pending: CENELEC and FM Standards).IndicationOptional 4½ digit LCD indicator.Temperature Limits Operation: -40 to 85ºC (-40 to 185 ºF).Storage: -40 to 120ºC (-40 to 250 ºF). Vibration EffectMeets SAMA PMC 31.1.Electromagnetic Interference EffectDesigned to comply with IEC 801.HardwarePhysical: according to IEC 61158-2 and conformity with the FISCO model.Electrical Connection1/2-14 NPT, PG 13.5 or M20 x 1.5.Material of Construction Injected low copper aluminum with polyester painting or 316 Stainless Steel housing, with Buna N O-rings on cover (NEMA 4X, IP67).Mounting With an optional bracket that can be installed on a 2" pipe or fixed on a wall or panel.Weight Without mounting bracket: 93 kg
Send Enquiry
Read More
JM400Junction Box for Fieldbus (Foundation Fieldbus, Profibus), HART and conventional instrumentation (4-20mA)Quotation DownloadsJM400 is junction box, specially designed to make easier fieldbus connections (FOUNDATION fieldbus, PROFIBUS), HART and conventional instrumentation 4-20 mA. The IP66/68W housing protection, combined with appropriate cable glands, protects the wire connections from dust, water, oil, and moisture. It may be used indoors or outdoors and can withstand the most severe environments.The JM400 design allows an easy access to the terminals, without using special tools. The terminals are twin type at the four ends. They can be used as the input and output of the bus according to the application convenience, keeping apart the wires that should be disconnected in case of device maintenance. This arrangement makes possible the disconnection of devices without disrupting the continuity of the whole segment.Allows easy and safe device connections to the fieldbus (FOUNDATION fieldbus, PROFIBUS), HART and also conventional instrumentation (4-20 mA).Ideal for coupling sensors, actuators and measuring instruments in hazardous areas or not.During maintenance prevents short-circuiting to the entire bus.Allows disconnecting devices without disrupting the continuity of the bus.Reduces wiring costs as well as minimizes design costs of the process control system.Reduces the startup time and simplifies electrical maintenance. Reduces the time of stops.The weather proof housing prevents water, oil and dust from reaching the electrical connections.4 inputs/outputs connections may be used according to the application convenience.Easy internal bus terminator accommodation.Aluminum and stainless steel construction.Cover’s locking mechanism.External grounding terminal.Does not require lugs.Spurs have protection against short circuits on the JM400-C3. The JM400-C3 offers protection against short circuits in the spurs (between + and – terminals), limiting the current to 50 mA on each. Thus, the short circuit does not propagate between the spurs nor in the main trunk. This option has short circuit indication LED and built-in terminator.In normal operation, each protection short-circuit has less than 1 mA of current consumption. After removing the short-circuit, the spur goes to normal operation and the protection circuit is disabled, turning off the LED. Technical Specifications of JM400-C3:Physical layer: according to IEC 61158-2, bus-powered 9-32 VdcApplication: for Profibus-PA and Foundation fieldbusMaximum Trunk Current: 2.5 AQuiescent current per spur in normal operation: <1.0mAMaximum current during a short-circuited per spur: 50mAMaximum drop voltage per spur: 0.3V @ 20mANumber of spurs: 2Terminator: 100 Ohm resistor and 1uF capacitor selectable by a switchShort-circuit status: through a LED: On (red) spur in short-circuit condition; Off: spur in normal operationSpur Connecting: Removable terminal blocks with screw 3-way 2.5 mm ²Housing Material: AluminumCover: 4 screws with o’ringMounting: for field mountingDegree of protection: IP 66/68Operating Temperature: -20 ° C to 70 ° CStorage: -40 ° C to 85 ° CRelative Humidity: 0-95% non-condensingExplosion proof: CEPEL certification
Send Enquiry
Read More
Page 2 0.9