The DT300 “Touché” Intelligent Density Transmitter
is an instrument developed for the continuous, online
measurement of liquid density and concentration, directly
in the industrial process.
Its pioneer technology consists of a capacitive type
differential pressure sensor coupled to a pair of pressure
repeaters immersed in the process. A temperature sensor
located between the two pressure repeaters is used to
compensate the temperature variations in the process fluid.
A dedicated software, by means of an algorithm, calculates
the fluid density.
Depending on the industrial process, density may be
expressed in g/cm3, Kg/m3, lb/ft3, Specific Gravity,
Brix degree, Gay-Lussac degree, Baumé degree,
Plato degree, INPM degree, API degree, Solids %,
Concentration %, etc.
Designed for process control applications, these 2-wire
transmitters generate a signal proportional to the
concentration/density. Digital communication for remote
calibration and monitoring is also provided.


# Accuracy ±0.0004 g/cm³ (±0.1 °Brix);
# Temperature compensation;
# Range 0.5 g/cm³ - 5 g/cm³;
# Standard industrial and sanitary process connection;
# Digital LCD indicator;
# Direct density or concentration readout in engineering units;
# Suitable for dynamic and static liquids;
# Two wire loop powered;
# Several different wetted materials;
# Single integrated unit without moving parts;
# Factory calibration and Self calibration;
In field re-calibration:
 No standard reference required;
 No lab calibration required;
 No process shutdown.
# Continuous/Self diagnostics;
# Weather proof, explosion proof and intrinsically safe;
# The control strategy is built from direct instantiation and 
     deletion of function blocks;
# Configuration and Parameterization all through open and 
    interoperable configuration tools available in the market, e.g., 
    based on PC or PCMCIA Cards or operations by the local
    adjustment switches (should be used with a LCD display);
# Use of the Analog Input function;
# Totally digital; including sensor, electronics and communication;
    Configurable Local Adjustment (Foundation fieldbusTM and 
     PROFIBUS PA);
# Easy firmware upgrade (via Flash Memory Interface) for 
    Foundation fieldbus TM and PROFIBUS PA;
# Easy maintenance;
# Three technology options: HART®, Foundation fieldbusTM, 
    PROFIBUS PA.

Density / Concentration Transmitter

assured purchase
True
Buy Now
Add to Cart
Need More Info
The DT300 “Touché” Intelligent Density Transmitter is an instrument developed for the continuous, online measurement of liquid density and concentration, directly in the industrial process. Its pioneer technology consists of a capacitive type differential pressure sensor coupled to a pair of pressure repeaters immersed in the process. A temperature sensor located between the two pressure repeaters is used to compensate the temperature variations in the process fluid. A dedicated software, by means of an algorithm, calculates the fluid density. Depending on the industrial process, density may be expressed in g/cm3, Kg/m3, lb/ft3, Specific Gravity, Brix degree, Gay-Lussac degree, Baumé degree, Plato degree, INPM degree, API degree, Solids %, Concentration %, etc. Designed for process control applications, these 2-wire transmitters generate a signal proportional to the concentration/density. Digital communication for remote calibration and monitoring is also provided. # Accuracy ±0.0004 g/cm³ (±0.1 °Brix); # Temperature compensation; # Range 0.5 g/cm³ - 5 g/cm³; # Standard industrial and sanitary process connection; # Digital LCD indicator; # Direct density or concentration readout in engineering units; # Suitable for dynamic and static liquids; # Two wire loop powered; # Several different wetted materials; # Single integrated unit without moving parts; # Factory calibration and Self calibration; In field re-calibration:  No standard reference required;  No lab calibration required;  No process shutdown. # Continuous/Self diagnostics; # Weather proof, explosion proof and intrinsically safe; # The control strategy is built from direct instantiation and deletion of function blocks; # Configuration and Parameterization all through open and interoperable configuration tools available in the market, e.g., based on PC or PCMCIA Cards or operations by the local adjustment switches (should be used with a LCD display); # Use of the Analog Input function; # Totally digital; including sensor, electronics and communication; Configurable Local Adjustment (Foundation fieldbusTM and PROFIBUS PA); # Easy firmware upgrade (via Flash Memory Interface) for Foundation fieldbus TM and PROFIBUS PA; # Easy maintenance; # Three technology options: HART®, Foundation fieldbusTM, PROFIBUS PA.
Buy Now
Add to Cart
Cash on Delivery
  • 2017-07-24T07:05:15
True
You might like these
Instrumentation Fittings
VIEW MORE
CAPACITANCE LEVEL SWITCH
VIEW MORE
Conductivity Transmitter
VIEW MORE
PH / ORP Transmitter
VIEW MORE
Magnetic Flow Meter
VIEW MORE
Smart Touch panel HMI
VIEW MORE
PLC - 200V
VIEW MORE
PLC - 300S
VIEW MORE
PLC - SLIO
VIEW MORE
Density / Concentration Transmitter
VIEW MORE
PH / ORP Transmitter
VIEW MORE
View all in Products